Apc Device Configuration Wizard Download
Messages in config.iniA feature might not be supported for the device from which you retrieve the configuration settings or might not be supported for the device to which you export the configuration settings. In this case, the user configuration file contains, under the section name for that feature, a message stating that the feature is not supported. No keywords and values are listed, and that feature will not be configured on any device to which you export the user configuration file. Errors generated by overridden valuesThe Override keyword and its value will generate error messages in the event log when it blocks the exporting of values.See Contents of the.ini file for information about which values are overridden.The overridden values are device-specificand not appropriate to export to other Rack PDUs. Therefore, you can ignore these error messages.
To prevent these error messages from occurring, you can delete the lines that contain the Override keyword and the lines that contain the values that they override. Do not delete or change the line containing the section heading. Using the APC Device IP Configuration WizardOn Windows operating systems, instead of using the preceding procedure for exporting.ini files, you can choose to update the basic TCP/IP settings of Rack PDUs by using the APC Device IP Configuration Wizard.See APC Device IP Configuration Wizard for a detailed description of how to discover and configure unconfigured Switched Rack PDUs remotely over your TCP/IP network or configure or reconfigure a Switched Rack PDU through a direct connection from the serial port of your computer to the Switched Rack PDU.
File Transfers Introduction OverviewThe Switched Rack PDU automatically recognizes binary firmware files. Each of these files contains a header and one or more Cyclical Redundancy Checks (CRCs) to ensure that the data contained in the file is not corrupted before or during the transfer operation.When new firmware is transmitted to the Rack PDU, the program code is updated and new features become available.This chapter describes how to transfer firmware files to Switched Rack PDUs.To transfer a firmware file to a Rack PDU, see UpgradingFirmware: Methods and Tools.To verify a file transfer, see Verifying Upgrades and Updates. Upgrading Firmware: Methods and Tools Benefits of upgrading firmwareUpgrading the firmware on the Switched Rack PDU has the following benefits:. New firmware has the latest bug fixes and performance improvements. New features become available for immediate use.
Keeping the firmware versions consistent across your network ensures that all Switched Rack PDUs support the same features in the same manner. Obtain the latest firmware versionAutomated upgrade tool for Microsoft Windows systems. An automated self-extractingexecutable tool combines the firmware modules that you need to automate your upgrades on any supported Windows operating system. The version of the tool on the APC Rack PDU Utility CD that came with your Rack PDU will upgrade your device to the latest AOS and application modules available when the CD was released. If a later firmware upgrade is available, you can obtain an updated version of the tool at no cost from the support section of the APC web site www.apc.com/tools/download.
Device Ip Configuration Utility
At this Web page, find the latest firmware release for your APC product (in this case, your Rack PDU) and download the automated tool, not the individual firmware modules.If the AOS firmware module you already have is a 1. X.x version, the executable tool must perform two consecutive upgrades:. The first upgrade is from version 1. X to the latest available 2.0. X version of the AOS firmware module. The second upgrade is from the 2.0.
Apc Ip Configuration Wizard Download
X version to the most recently released version of the AOS module.The tool therefore contains firmware modules for both upgrades.Each upgrade tool is specific to an APC product type. Do not use the tool from one product CD to upgrade firmware of a different APC product. If you use a version of the tool from the APC Web site, make sure that you use the upgrade tool that corresponds with your APC product type. Manual upgrades, primarily for Linux systems. If all computers on your network are running Linux, you must upgrade the firmware of your Rack PDUs manually, i.e., by using the separate APC firmware modules (AOS module and application module).If you have a networked computer running a supported Microsoft Windows operating system on your network, you can use the tool described in Automated upgrade tool for Microsoft Windows systems to upgrade the firmware of a Switched Rack PDU automatically over the network. This tool automates the entire upgrade process, even if your current firmware is a 1.
X.x version.When performing a manual upgrade, not using the automated tool, you cannot upgrade the AOS firmware module of any APC device directly from firmware version 1. X.x to firmware version 2.1.0 or later. The upgrade attempt will fail.
You must first upgrade to the latest available 2.0. X version of the AOS module and then to the later version.You can obtain the individual firmware modules you need for a manual firmware upgrade from the support section of the APC Web site www.apc.com/tools/download. Use FTP or SCP to upgrade one Rack PDUInstructions for using FTP.
For you to be able to use FTP to upgrade a single Switched Rack PDU over the network:. The Switched Rack PDU must be connected to the network. The FTP server must be enabled at the Switched Rack PDU.
The Switched Rack PDU must have its TCP/IP settings ( System IP, Subnet Mask, and Default Gateway addresses) configured.To use FTP to upgrade the Rack PDU:1. Open an MS-DOScommand prompt window on a computer that is connected to the network. Go to the directory that contains the firmware upgrade files, and list the files. For the directory C:apc, the commands would be those shown in bold:C:cdapcC:apc dirFiles listed for a Switched Rack PDU, for example, might be the following:– apchw02aos264.bin– apchw02app266.bin2. Open an FTP client session:C:apc ftp3.
Type open and the Switched Rack PDU’s IP address, and press E NTER. If the Port setting for FTP Server in the Network menu has changed from its default of 21, you must use the non-defaultvalue in the FTP command.a. For some FTP clients, use a colon to add the port number to the end of the IP address.b. For Windows FTP clients, separate the port number from the IP address by a space. For example, if the Rack PDU’s FTP Server Port setting has been changed from its default of 21, such as to. 21000, you would use the following command for a Windows FTP client transferring a file to a Rack PDU with an IP address of 150.250.6.10.ftp open 150.250.6.10 210004.
Log on using the Administrator user name and password. ( apc is the default for both.)5. Upgrade the AOS. For example:ftp binftp put apchw02aos264.bin6. When FTP confirms the transfer, type Quit to close the session.7.
Wait 20 seconds, and then repeat step 2 through step 6, but in step 5, use the application module file name instead of the AOS module.Instructions for using SCP. To use Secure CoPy (SCP) to upgrade the firmware for one Rack PDU:1. Identify and locate the firmware modules described in the preceding instructions for FTP.2. Use an SCP command line to transfer the AOS firmware module to the Rack PDU. The following example assumes a Rack PDU IP address of158.205.6.185, and an AOS module of apchw02aos264.bin.)scp apchw02aos264.bin apc@158.205.6.185:apchw02aos264.bin3. Use a similar SCP command line, with the name of the application module instead of the AOS module, to transfer the application module to the Rack PDU. How to upgrade multiple Rack PDUsExport configuration settings.
You can create batch files and use an APC utility to retrieve configuration settings from multiple Rack PDUs and export them to other Rack PDUs.